| SP-4000 | Model Number | SP-2000c |
![]() |
Specifications | |
| Output Power |
2000 W Continous Power 4000 W Surge Power |
|
| Standby Current | < 0.6 A | |
| Input Voltage | DC 20V-30V | |
| Output Voltage | AC 100V, 110V, 120V, 220V,230V, 240V |
|
| Output Waveform | Modified Sine Wave | |
| Efficiency | >85% | |
| » Initial Checking | Auto Detecting Wrong Battery Cont. ex. 12V / 24V |
|
| » Output Regulation | ± 5% Intelligent PWM | |
| » Output Frequency | 50Hz or 55Hz or 60 Hz Crystal Controlled |
|
| » Cooling | Auto Operation Fan | |
| PROTECTIONS : | ||
| » Output Short | Output Short Circuit Protection | |
| » Low Battery | <21.5V ± 0.5V Pre Alarm <20.5V ± 0.5V Shutdown & Alarm |
|
| » Over Heating | >60°C ± 5°C Pre Alarm >65°C ± 5°C Shutdown & Alarm |
|
| » Overload | >2000 W Pre Alarm >2200 W Shutdown & Alarm |
|
| Battery Polarity Everse | By Fuse | |
| Fuse | 10A * 16 Pcs | |
| AC Outlet | 3 AC Outlets European Types: 2 AC Outlets |
|
| Automatical Switch
Transfer Time |
AC Line -> inverter Inverter -> AC Line AC Line -> inverter 16 ms |
|
| Dimension
Charger Current |
420 x 169 x 152mm (LxWxH)
5 Amp |
|
| Net Weight | 10 Kg |